CNVTYPE type {0}


This keyword specifies the method of incident-particle spectrum conversion using the GRPCONVERT keyword. The default 0 value uses an equal-lethargy per bin approximation to convert flux values over bin boundaries while using 1 causes the conversion to use an equal-energy approximation. Example usage:

< -- Control phase -- >
...
CNVTYPE 1
GRPCONVERT 175 709
FISPACT
* Title of the simulation
< -- Initial phase -- > 
...
< -- Inventory phase -- > 
...