Keyword:CNVTYPE
From FISPACT-II Wiki
CNVTYPE type {0}
This keyword specifies the method of incident-particle spectrum conversion using the GRPCONVERT keyword. The default 0 value uses an equal-lethargy per bin approximation to convert flux values over bin boundaries while using 1 causes the conversion to use an equal-energy approximation. Example usage:
< -- Control phase -- > ... CNVTYPE 1 GRPCONVERT 175 709 FISPACT * Title of the simulation < -- Initial phase -- > ... < -- Inventory phase -- > ...